Trust
What each status badge means, what every module was checked against, and where the tools stop being reliable.
Every calculator carries one of three badges. They describe how much checking stands behind it today, not how good the idea is.
"Validated" does not mean certified, and it does not mean tested against plant measurements. Every check listed here compares the code with a reference design calculation or a published example, so it shows the method is implemented correctly, not that it predicts a real boiler to that accuracy. A module can agree with one reference design to a few percent and still be wrong for a boiler that differs from it, so the limitations further down matter as much as the badge.
| Module | Status | What it was checked against |
|---|---|---|
| Air Preheater | Reference-based | Overall U within about 0.5% of a private reference calculation. |
| Humid Air Thermodynamic Properties | Reference-based | Standard psychrometric relations and species-based transport properties. |
| Ash Deposit Growth | Validated | Checked against the author's reference workbook, including vapor diffusivities and saturation pressures. |
| Ash Melting Analysis — Biomass & Coal | Reference-based | Classical slagging and fouling indices plus a ternary phase estimate, from published methods. |
| Ash Melting Analysis — RDF & MSW | Reference-based | Same published indices, plus a worst-case screen for heavy-metal chloride systems. |
| Basic Combustion | Validated | Cross-checked against two independent published sources and an independent process-simulation workbook. |
| Boiler Capacity | Validated | Direct-method duty and efficiency checked against a reference boiler design (differences under 0.01%). |
| Desuperheater | Preliminary | Built from the enthalpy-mixing balance; not yet checked against a reference case. |
| Economizer | Reference-based | Duty within about 0.1% and overall U within about 2% of a private reference calculation; solved outlet temperature within 0.3 °C. |
| Emission | Reference-based | Published NOx, SOx and dust relations; not checked against a plant emissions record. |
| Electrostatic Precipitator (ESP) | Reference-based | Corona onset, operating voltage and current density match a reference; the migration-velocity and efficiency stage is still under review. |
| Evaporation Wall Chamber | Reference-based | Wall area and mean radiating length match the reference; duty within about 0.2%, overall U within about 5%. |
| Evaporator Bank — Downcomer | Preliminary | Same engine and defaults as the Riser; not checked against a downcomer case. |
| Evaporator Bank — Riser | Reference-based | Areas match the reference; duty within about 0.1%, overall U within about 5%. |
| Industrial Fan Design & Fan Curve Calculator | Reference-based | Standard backward-curved centrifugal fan design equations and fan-law relations. |
| Fixed-Bed Firing Model | Reference-based | Built from the author's own model and published paper; not checked against a full-scale grate. |
| Flue Gas Temperature Profile | Reference-based | Experience-based guideline ranges. This is a design choice, not a solved result. |
| Flue Gas Thermal Properties | Validated | Species heat capacities checked against a textbook source; gas radiation checked end to end against a reference workbook. |
| Fly Ash Particle Density and Electrical Properties — Biomass | Reference-based | Biomass resistivity model; results are directionally consistent with published literature but not checked against a worked case. |
| Fly Ash Particle Density and Electrical Properties — Coal | Validated | Bickelhaupt (EPRI CS-4145) correlation checked against a published worked example, within a few percent. |
| Fuel Data — Single Fuel | Reference-based | Published proximate, ultimate and ash-oxide data for common Thai biomass fuels; user-entered fuels are converted between as-received and dry bases. |
| Fuel Data — Mixed Fuel Blend | Reference-based | Mass-weighted blending of the single-fuel analyses. |
| Furnace Heat Transfer | Reference-based | Overall heat transfer coefficient within about 3% of a private reference calculation. |
| Radiation Heat Drop Chamber | Reference-based | Uses the validated Furnace engine; not separately checked against a chamber design. |
| Screen Tube Heat Transfer | Reference-based | Overall U within about 6% of a private reference calculation. The remaining gap traces to inputs in the reference, not the correlation. |
| Steam Drum | Preliminary | Built from the enthalpy and mass balance of a flash drum; not yet checked against a reference case. |
| Steam Table — Standard Range | Validated | IAPWS-IF97 industrial formulation, regions 1, 2 and 4, checked against standard published reference values (e.g. Tsat=179.886°C at 10 bar). |
| Steam Table — Extended Range | Reference-based | IAPWS-IF97 industrial formulation, regions 3 and 5. |
| Superheater Heat Transfer | Reference-based | Duty within about 0.1% and overall U within about 7% of a private reference calculation; steam outlet temperature is solved, not assumed. |
| Suspension Firing Boiler | Reference-based | Built from the author's own model; not checked against a full-scale furnace. |
| Thermoelectric Generator | Reference-based | The Ioffe maximum-efficiency equation (A.F. Ioffe, 1957) for an ideal thermoelectric leg, confirmed against multiple independent academic sources (PNAS, AIP Advances, arXiv). Material-property defaults are generic Bi₂Te₃-class order-of-magnitude values, not a specific commercial module's datasheet. Not yet checked against a published numeric worked example. |
| Deaerator Thermal & Mass Balance | Reference-based | Standard direct-contact heater energy balance using the shared IAPWS-IF97 engine. The 110–120°C standard vs up to ≈150°C elevated-pressure guidance (for acid-dew-point margin) reflects common power-plant practice; not checked against a published numeric worked example. |
| Deaerator Storage Tank Sizing | Reference-based | The 10-minute (5–30 minute practical range) retention-time guideline is drawn from American Boiler Manufacturers Association technical guidance. Vessel diameter/length from L/D ratio is a rough mechanical estimate, not a vendor-grade sizing calculation. |
| Deaerator NPSH & Elevation | Reference-based | Standard boiler-feed-pump suction design practice (e.g. Grundfos Boiler Feed Manual) — NPSHa from a saturated tank reduces to elevation minus friction loss since tank pressure and vapor pressure cancel. Not checked against a published numeric worked example. |
| Deaerator Droplet Heat/Mass Transfer | Reference-based | Whitaker's correlation (AIChE J., 1972) for droplet heating, applied as published deaerator-stripping research does; Crank's transient-diffusion-in-a-sphere solution for oxygen stripping. Known gap, disclosed on the module page: Whitaker's correlation under-represents the true condensation heat transfer rate (it omits the latent-heat effect at the droplet surface) — early experimental work (Brown, 1951) measured coefficients roughly 50× higher for comparable droplet sizes, so treat the heating-time estimate as a conservative upper bound. Spray-nozzle droplet-formation physics and tray/vessel mechanical sizing are intentionally out of scope. |
| Turbine Off-Design / Part-Load | Reference-based | Stodola's Ellipse (Cone) Law (A. Stodola, 1927; D.H. Cooke, ASME 1984) — the same method commercial plant-simulation software uses for this calculation. Checked for internal self-consistency (feeding the design point back through the solver reproduces it to 0.000000% in all three solve modes), not yet against a published numeric worked example. Assumes an infinite-stage, unchoked group. |
| Condensing Pressure from Cooling System | Reference-based | Standard Approach/Range/TTD (water-cooled) and ITD (air-cooled) power-plant cooling-system design method, with typical-value ranges drawn from published industry sources. Not yet checked against a complete published worked example the way the Turbine module was — confirm against vendor cooling-tower/ACC performance data for a real design. |
| Steam Turbine Expansion & Extraction | Validated | Checked against D.J. Dunn, Applied Thermodynamics Tutorial 1 (freestudy.co.uk), Worked Examples 3 & 5: single-stage back-pressure flow rate within 0.4% (109.05 vs 109.51 kg/s); two-stage pass-out/extraction flow rate within 2% (36.6 vs 37.34 kg/s) — the larger gap traces to the textbook's hand-drawn straight-line h-s chart approximation for the intermediate extraction enthalpy, versus this module's stage-by-stage isentropic-efficiency calculation, which is the more rigorous of the two methods. |
| Thermal Head | Reference-based | Standard Darcy-Weisbach downcomer friction and a circulation-ratio approximation, informed by published pressure-dependent CR guidelines (V. Ganapathy; Elgandelwar, Jha & Lele, 2020 — see Sources below). A screening check on circulation, not a flow solver. |
| Volatile Gas Combustion | Reference-based | Simplified global-reaction proxy for released volatile gas. |
The calculators implement published methods, and the credit belongs to their authors: Zukauskas (1972) for tube-bank cross-flow convection; Hottel-type total-emissivity methods for gas radiation, following polynomial forms in the literature; the IAPWS-IF97 industrial formulation for water and steam properties; Sutherland's law (coefficients from Crane TP-410 and the CRC Handbook) and Eucken's relation for gas transport properties; a Jakob-type friction correlation for tube-bank pressure drop; Peek-type corona onset, White's current-density relation, and Deutsch-Anderson and Matts-Ohnfeldt collection efficiency for the ESP; and the Bickelhaupt method (EPRI CS-4145) for coal fly ash resistivity. The row-count correction table for tube banks is adapted from the open-source ht library by Caleb Bell (part of the Chemical Engineering Design Library, ChEDL), released under the MIT License, reproduced below in full as required by that license. The Thermal Head module's circulation-ratio guideline range is informed by V. Ganapathy's widely-cited natural-circulation design charts (CR roughly 4–8 at high steam pressure, 15–50 at low pressure), as referenced and further developed with a similar pressure-dependent curve in A. M. Elgandelwar, R. S. Jha & M. M. Lele, "Desired Circulation Ratio for Natural Circulation in Water-Tube Boiler," International Journal of Recent Technology and Engineering, Vol. 8, Issue 5, January 2020, DOI: 10.35940/ijrte.E6646.018520 — the fitted curve used on this site is our own regression against guidelines of this kind, not a reproduction of either source's exact figures. The Steam Turbine Expansion & Extraction module's isentropic-efficiency stage method and worked validation cases are drawn from D.J. Dunn, Applied Thermodynamics Tutorial 1 — Advanced Steam Cycles, freestudy.co.uk, a freely published engineering tutorial. Where a module relies on a specific paper or data set, it is cited on that module's page.
The reference fuels in the Fuel Data module each carry a short source code next to their proximate/ultimate values. Confirmed sources: entries labeled Madhiyanon or Prof. Thanit are drawn from Assoc. Prof. Dr. Thanit Medhiyanon, “Theory and Technology of Solid Fuel and Biomass Combustion” (“ทษฐีเละเทคโนโลยีการเผาไหม้เชื้อเพลิงแข็งและชีวมวล"). Rubber wood's proximate/ultimate analysis is drawn directly from the TISTR ANBOR biomass database (Thailand Institute of Scientific and Technological Research), entry #19, tested to ASTM D7582/D5373/D4239/D5865. EFE, ERI, CMU, KU and EGAT are, respectively, the short forms of the Energy for Environment Foundation, the Energy Research Institute at Chulalongkorn University, Kasetsart University, Chiang Mai University and the Electricity Generating Authority of Thailand — all real institutions that this kind of data commonly comes from in Thailand, but since the specific underlying report behind each individual table entry hasn't been traced and confirmed, those entries are now labeled Typical range rather than attributed to a specific institution, to avoid overstating how well-sourced each number is.
Ash oxide composition (SiO₂, Al₂O₃, CaO, K₂O and so on) for the fuels marked Typical range in the Ash Source field is presented as an indicative, order-of-magnitude reference rather than a traceable lab assay — ash chemistry in particular varies widely by region, soil and plant variety, so a specific named source for this field would overstate its precision. Use your own tested ash analysis for any real design decision; the TISTR ANBOR database is a free starting point for Thailand-representative proximate/ultimate data, though it does not currently publish detailed ash oxide breakdowns.
Source: github.com/CalebBell/ht. Only the row-correction table is used here; PlantAISim's own calculators are original code and not part of the ht package.
Compare it with supplier data or an independent calculation, and have a qualified engineer review anything that affects safety, guarantees or purchasing. See also the Terms & Disclaimer.
Found a difference from your own data or a reference? Email [email protected]. Corrections are how this page improves.