Evaporator Bank — Downcomer

Preliminary what this means

The downcomer side of an evaporator bank tube bundle — positioned further along the gas path than the Riser bank, cooler flue gas, and typically closer to saturated liquid (little or no vapor yet, since it carries water back toward the lower drum/bottom header) though the module stays flexible for whatever inlet dryness actually applies. Same Zukauskas (1972) tube-bank engine as the Riser variant — named separately so the two can be linked independently once cross-module Natural Circulation solving is built.

? New here? How to use this calculator

What this answers: Required tube surface for the downcomer side of an evaporator bank — the cooler, liquid-heavy half of the tube-bank pair.

The numbers already in the fields are a complete, working example — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Flue Gas (from Temperature Profile)
kg/hr
°C
°C
bar
Gas Composition (mol%, wet basis)
Tube Bank Geometry
mm
mm
mm
mm
row-correction factor is looked up automatically below
m — used for both Ao/Ai and the boiling correlation
m
m — net open height between tube rows/headers
Water/Two-Phase Side
barg
bar — at the boiler's installation elevation
may already be partially evaporated, or close to saturated liquid for a downcomer — enter your own value
kg/hr
Tube Wall & Fouling?
W/m·K
micron
W/m·K
mm — commercial steel tube, typical
% of gas-side Q — typical 1.5-3%

Duty & Natural Circulation?

Heat Transfer Coefficients?

Pressure Drop

Heating Surface?

Radiation: same Hottel-type engine as Furnace/Flue Gas Thermal Properties, but Mean Radiating Length uses the tube-bank form L=Factor×(Pitch−D) instead of 3.5×V/A. Convection: Zukauskas (1972) — V_max from the free-stream velocity via an arrangement-dependent factor, Re_max on that velocity, C1/m coefficients depending on Re_max range and ST/SL ratio, with a row-count correction factor. Ao=π×OD×L×N and Ai=π×ID×L×N (full circumference both sides — individual tubes with gaps, unlike Furnace's membrane wall where only Ao uses the full diameter and Ai is halved). Inlet dryness fraction is a direct input since Screen Tube commonly receives already-partially-evaporated flow rather than starting from saturated liquid. This module reports Actual (from your tube-length input) vs Required (from U×LMTD) heating surface as a Rating check.