Feedwater heater — receives subcooled liquid water from the Deaerator via the high-pressure feed pump, heats it before the drum. Same Zukauskas gas-side convection and Hottel radiation engine as Screen Tube; tube side is single-phase liquid water (IAPWS Region 1), Dittus-Boelter, no boiling. Outlet temperature is solved from energy balance + pressure drop (like Superheater), not assumed. Wall temperature uses the real reference formula: average bulk water temperature + 30°C margin (no saturation temperature to anchor to, unlike the boiling sections).

? New here? How to use this calculator

What this answers: How much tube surface is needed to preheat feedwater with leftover flue gas heat before it reaches the drum.

The numbers already in the fields are a complete, working example — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Flue Gas (from Temperature Profile)
kg/hr
°C
°C
bar
Gas Composition (mol%, wet basis)
Tube Bank Geometry
mm
mm
mm
mm
gas-flow-direction row count — for the Zukauskas row-correction factor ONLY. Different from Number of Tubes (below) which sets water velocity.
simple total count, not split into panels here
m — back-solved from the real Heating Surface; likely a multi-pass/finned coil, not a simple straight run
m
m — net open height, tubes already subtracted
mm — bare tube bank (not membrane wall), commercial-steel range
Water Side
kg/hr
°C — from Deaerator via the high-pressure feed pump
°C — solved from energy balance + pressure drop; this is just the iteration starting point
barg — feed pump discharge pressure, near drum pressure
barg
bar — at the boiler's installation site
mm
Tube Wall & Fouling?
W/m·K
micron
W/m·K — lower end of the bagasse-ash range used here (vs 0.338 elsewhere)
% of gas-side Q — typical 1.5-3%

Duty

Heat Transfer Coefficients?

Pressure Drop

Heating Surface?

Radiation: same Hottel-type engine as Furnace/Screen Tube, Mean Radiating Length via L=Factor×(Pitch−D). Gas-side convection: Zukauskas (1972), same branch logic and digitized row-correction table as Screen Tube. Water side: single-phase liquid (IAPWS Region 1) Dittus-Boelter both directions (no boiling), properties averaged inlet/outlet, outlet state solved from energy balance + pressure drop. Ao=π×OD×L×N, Ai=π×ID×L×N (individual tubes with gaps, not a membrane wall). Tube count sets water velocity (see the guidance panel); tube length reconciles Actual vs Required heating surface. Pressure drop: gas-side uses a Jakob-type tube-bank friction-factor correlation; water-side uses standard single-phase Darcy-Weisbach (Colebrook) plus elevation.