PlantAISim

Fouling & Corrosion / Boiler Tube Deposit

Ash Deposit Growth

Validated what this means

Iterative, time-marching deposit thickness — condensation (KCl/KOH/K2SO4), inertial impaction and thermophoresis, averaged across 19 equally-spaced angles around the tube (0°-180°), with the deposit's own growing thermal resistance feeding back into surface temperature and a Loose→Sintered→Molten state transition.

Built from and cross-checked against a real, more detailed 40-angle Excel reference model — the implicit thermal balance, under-relaxation, and Antoine saturation-pressure equations are taken directly from it. The reference model's own angle-summation (not averaging) was found to inflate total flux roughly 40x, compensated only partially by an unrelated tube-count division — this web version corrects that with a direct, dimensionally-consistent average.

? New here? How to use this calculator

What this answers: How thick an ash deposit grows on a tube surface over time, and how much that growing layer insulates the tube and raises its surface temperature.

The numbers already in the fields are a complete, working example — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Simulation
hr (default: soot-blow interval)
min
Tube & Duct Geometry
mm
mm
m
m
Flue Gas
°C
m³/hr
Pa·s
kg/m³
W/m²K
Ash Oxide Composition (wt%)
%
Skeletal (true) density— kg/m³
Bulk (apparent) density — used below— kg/m³

Same formula as the Fly Ash Particle Density & Electrical Properties module: True density × (1−particle porosity) + moisture term + gas term. This single computed value now drives both the impaction Stokes number and the flux→thickness conversion below — no separate manual density inputs.

Vapor & Fly Ash (bulk, free-stream)
kg/m³
kg/m³
kg/m³
kg/m³
µm
Tube Metal & Deposit
°C
°C
°C — from eutectic/melting DB

Deposit Growth?

Final State (end of duration)

Method note. The Antoine saturation-pressure equations (KCl/KOH/K2SO4), the Sherwood-number condensation form, and the implicit thermal-balance + under-relaxation fix for numerical oscillation are all taken from and cross-checked against a real, detailed 40-angle Excel reference model built for one EFB case. That reference model's own angle-summation approach (rather than averaging) was found — together with its author — to inflate total flux by roughly 40x, so absolute thickness numbers here should not be expected to match it; this web version uses the dimensionally-correct average instead. The fly ash capture-efficiency correlation uses a standard literature form (Stk/(Stk+0.25))² pending exact cross-check against the source spreadsheet's internal formula. No independent field measurement exists yet to calibrate absolute growth rates — treat results as directionally informative pending real plant data.

Quick reaction — was this calculator useful?

Was this calculator useful? Tell us what's missing or what you'd like to see next.