Fouling & Corrosion / Boiler Tube Deposit
Iterative, time-marching deposit thickness — condensation (KCl/KOH/K2SO4), inertial impaction and thermophoresis, averaged across 19 equally-spaced angles around the tube (0°-180°), with the deposit's own growing thermal resistance feeding back into surface temperature and a Loose→Sintered→Molten state transition.
Built from and cross-checked against a real, more detailed 40-angle Excel reference model — the implicit thermal balance, under-relaxation, and Antoine saturation-pressure equations are taken directly from it. The reference model's own angle-summation (not averaging) was found to inflate total flux roughly 40x, compensated only partially by an unrelated tube-count division — this web version corrects that with a direct, dimensionally-consistent average.
What this answers: How thick an ash deposit grows on a tube surface over time, and how much that growing layer insulates the tube and raises its surface temperature.
The numbers already in the fields are a complete, working example — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.
Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.