PlantAISim

Combustion & Emissions / Advanced Combustion Models

Volatile Gas Combustion

Reference-based what this means

A simplified proxy for released volatile-matter gas: all Volatile Carbon is treated as releasing in the form of CO (the standard fuel-C→CO→CO2 global combustion picture), and all fuel Hydrogen as H2, assumed to burn instantaneously. Tracks whether the released CO fully oxidizes within the furnace's plug-flow residence time given a measured/estimated furnace temperature, or escapes partially unburned — the Volatile-firing LHV budget from Basic Combustion serves as a reference ceiling, not a forced target.

? New here? How to use this calculator

What this answers: A simplified check on whether the gas released when fuel volatiles burn off actually finishes burning before it leaves the furnace.

The numbers already in the fields are a complete, working example — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Fuel A
Combustion Conditions
%
blank = 1.2+0.002×M
kg/hr
Furnace Plug-Flow Residence Time
m
m/s
°C — used for both residence-time gas properties and CO kinetics

Residence time = Furnace height ÷ Gas upflow velocity — a plug-flow screening estimate, not a CFD result. A single gas temperature is used throughout (a real furnace has a temperature profile; this is a deliberate simplification).

Volatile Split (H2 / CO / CO2)

CO Burnout Tracking

H2 combustion is assumed instantaneous — not calculated from kinetics. This is a common engineering simplification (H2 oxidizes far faster than CO) but is a modeling assumption, not a computed result. All Volatile Carbon is assumed to release as CO (the standard two-step global combustion picture: fuel-carbon → CO first, then CO → CO2), tracked via CO kinetics — Howard, Williams & Fine (1973) global rate, d[CO]/dt = −1.3×10¹¹·exp(−15105/T)·[CO][H2O]0.5[O2]0.25, evaluated at the single gas temperature above (not a real temperature profile). The Volatile-firing LHV budget is a ceiling, not a target forced to match — if CO burns out 100%, modeled heat approaches the budget; any CO that doesn't burn out within the residence time represents real incomplete-combustion heat loss. CH4 and tar/heavier hydrocarbons are not modeled — where max-possible H2+CO heat falls well short of the budget, that gap reflects unmodeled tar/CH4 contribution, not an error.

Quick reaction — was this calculator useful?

Was this calculator useful? Tell us what's missing or what you'd like to see next.

Send Feedback