PlantAISim

Boiler Heat Transfer Train / Steam-Water Separation

Steam Drum

Preliminary what this means

Thermodynamically, the drum is a flash tank: two-phase mixture arrives from the risers (grouped here as Furnace-side and Evaporator-side circuits, add/remove as your boiler's actual routing requires), steam is separated by the cyclone/demister, and the remaining saturated liquid mixes with incoming Economizer feedwater by enthalpy balance to set the drum water temperature (slightly subcooled below T_sat, not exactly at it).

? New here? How to use this calculator

What this answers: Checks the drum's mass and energy balance: how much of the incoming two-phase flow actually leaves as steam, and what temperature the drum water settles at.

The numbers already in the fields are a complete, working example — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Drum Conditions
barg
kg/hr — design target; used to cross-check the circuit inputs below
bar
Furnace-side Riser Circuits

Each circuit's own total 2-phase flow (kg/hr) and heat duty (kW) — e.g. Furnace, Radiation/Evaporation Wall Chamber, Screen Tube (if routed here). Steam generated per circuit = Q/h_fg.

Evaporator-side Riser Circuits

Each circuit's own total 2-phase flow (kg/hr) and heat duty (kW) — e.g. Evaporation Bank Tube, Screen Tube (if routed here instead).

Economizer Feedwater
kg/hr
°C — Economizer's own solved outlet

Two-Phase Mass & Steam Balance?

Drum Water Enthalpy Mixing

Mass Balance Check

Steam generated per circuit = Q/h_fg (h_fg at drum saturation conditions, same convention as Furnace/Screen Tube/Evaporator Bank). Saturated liquid returning to the drum pool = Total 2-phase flow in − Total steam generated. Drum water enthalpy: h_mix=(ṁ_satliq·h_L+ṁ_feedwater·h_feedwater)/(ṁ_satliq+ṁ_feedwater); T_water is recovered by inverting the steam table at (h_mix, P_drum) — the same bisection approach used in Superheater/Economizer/Desuperheater. At steady state, total steam generated should equal feedwater flow (ignoring blowdown) — the balance check flags a meaningful mismatch as a sign the circuit inputs may be incomplete or inconsistent.