Boiler Heat Transfer Train / Overall Capacity

Boiler Capacity

Validated what this means

Direct-method boiler duty and efficiency — steam output and feedwater enthalpies from the IAPWS-IF97 steam tables, fuel energy from LHV. Solve for required fuel rate given a target efficiency, or check the efficiency implied by a given fuel rate. This is the starting point of the boiler design chain: every downstream heat-transfer module (Furnace, Superheater, Evaporator, Economizer, APH) works to a flue-gas temperature profile sized against this duty.

? New here? How to use this calculator

What this answers: Given steam output and fuel heating value, either the fuel rate you'll need or the efficiency a given fuel rate implies. The starting point for every other module downstream.

The numbers already in the fields are a complete, working example — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Steam Output
kg/hr
°C
bara
Feed Water Input
kg/hr
°C — typically Deaerator design T, 100-120°C
bara
Fuel
kJ/kg — from Basic Combustion
kg/hr

Steam & Feedwater Enthalpy

Boiler Duty & Direct Efficiency

Direct Method: η = (M_steam×H_steam − M_feedwater×H_feedwater) / (M_fuel×LHV) × 100. Steam and feedwater enthalpies come from the IAPWS-IF97 formulation (same validated engine as the Steam Table module) — Region 1 (compressed liquid) for feedwater, Region 2 (superheated vapor) for steam output. This module assumes the feedwater temperature is genuinely subcooled liquid and the steam output is genuinely superheated vapor at the pressures given; it does not check region validity automatically.