Waste Heat Recovery / Thermoelectric
No moving parts, no working fluid — a thermoelectric module turns a temperature difference straight into electricity via the Seebeck effect. Screens whether a hot surface or low-grade flue gas stream (too small or too cool to justify a turbine) is worth tapping with one, using the classic Ioffe maximum-efficiency equation.
What this answers: given a hot side and cold side temperature and a thermoelectric material's properties (or just its ZT if that's all you have), what's the best-case conversion efficiency, and how much power a given module footprint could realistically produce.
Pick your starting point with the mode buttons below: enter the three material properties directly if you have a datasheet, or just the figure of merit ZT if that's all you know.
The numbers already in the fields are a plausible example — not a template you must match, and not any specific commercial module's datasheet. Overwrite them with your own material's values; the results update as you type.
Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.
Real modules run below this ideal-leg efficiency once contact resistance, insulation losses and non-optimal load matching are included — treat this as a best-case screening number.
Quick reaction — was this calculator useful?
Was this calculator useful? Tell us what's missing or what you'd like to see next.