PlantAISim

Waste Heat Recovery / Thermoelectric

Thermoelectric Generator

Reference-based what this means

No moving parts, no working fluid — a thermoelectric module turns a temperature difference straight into electricity via the Seebeck effect. Screens whether a hot surface or low-grade flue gas stream (too small or too cool to justify a turbine) is worth tapping with one, using the classic Ioffe maximum-efficiency equation.

? New here? How to use this calculator

What this answers: given a hot side and cold side temperature and a thermoelectric material's properties (or just its ZT if that's all you have), what's the best-case conversion efficiency, and how much power a given module footprint could realistically produce.

Pick your starting point with the mode buttons below: enter the three material properties directly if you have a datasheet, or just the figure of merit ZT if that's all you know.

The numbers already in the fields are a plausible example — not a template you must match, and not any specific commercial module's datasheet. Overwrite them with your own material's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Operating Temperatures
°C
°C — cooling water/air side
Material Figure of Merit?
commercial Bi₂Te₃ modules typically run ≈0.8–1.2 near room temperature
Module Footprint (for power estimate)
kW — thermal power reaching the hot side

Figure of Merit

Maximum Conversion Efficiency — Ioffe Equation?

Power Output Estimate

Real modules run below this ideal-leg efficiency once contact resistance, insulation losses and non-optimal load matching are included — treat this as a best-case screening number.

Reference-based. The Ioffe maximum-efficiency equation (A.F. Ioffe, 1957) is the standard textbook result for an ideal thermoelectric leg with temperature-independent properties, confirmed against multiple independent academic sources. ZT = α²T⁄(ρκ) is the standard dimensionless figure of merit. The material property defaults are generic, order-of-magnitude typical values for Bi₂Te₃-class thermoelectric materials — not a specific commercial module's datasheet — enter your own module's values when you have them. Not yet checked against a published numeric worked example. See Validation & Limitations.

Quick reaction — was this calculator useful?

Was this calculator useful? Tell us what's missing or what you'd like to see next.