Deaerator / NPSH

Deaerator NPSH & Elevation

Reference-based what this means

Because the deaerator's water sits right at its boiling point, raising the tank's operating pressure doesn't help the pump at all — the vapor pressure rises right along with it. Elevation above the pump is the only thing that actually creates NPSH margin.

? New here? How to use this calculator

What this answers: the minimum height to lift the deaerator above the boiler feed pump's centerline so the pump doesn't cavitate — the single most common reason a boiler feed pump trips on low suction pressure.

NPSH required comes from your pump vendor's curve. If you don't have it yet, the dropdown gives a typical range to start a screening estimate from.

The numbers already in the fields are a plausible example, not a template you must match. Overwrite them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Pump NPSH Required?
m — most industrial BFPs run 1.5–8 m; large high-speed units can exceed 60 m and need a booster pump
Suction Piping & Safety Margin
m — estimate, or leave small if pipe is short/large-bore
m — commonly 0.5–2 m above NPSHr

Why Pressure Doesn't Help

Required Elevation

Reference-based. NPSHa from a saturated tank reduces to elevation minus suction friction loss, because tank pressure and liquid vapor pressure cancel — standard boiler-feed-pump suction design practice (e.g. Grundfos Boiler Feed Manual; Power magazine, "Can Your Boiler Feed Pump Handle a Deaerator Pressure Transient?"). The 6–15 m elevation range commonly seen in real installations reflects this directly. See Validation & Limitations.