Terms that recur across several calculators, defined once here. Each module links to the specific entries it uses — you don't need to read this page top to bottom before starting.

Heat transfer surface

Ao / Ai outside / inside area
The heat-transfer surface area of a tube bank, measured on the outside (gas side, usually) or inside (water/steam side). Ao = π × outside diameter × tube length × number of tubes; Ai uses the inside diameter instead. Overall U is normally quoted per unit of Ao, so the inside-film resistance gets scaled by Ao/Ai to stay consistent.
Overall U overall heat transfer coefficient
How easily heat crosses from gas to water/steam through everything in the way: gas film, tube metal, ash fouling, water film. A single number combining all those resistances in series. Higher U means more heat gets through for the same area and temperature difference.
LMTD log-mean temperature difference
The "driving force" temperature difference between the hot and cold streams, averaged properly along the length of the exchanger rather than as a simple arithmetic mean. Required area = Duty ÷ (U × LMTD).
Mean radiating length
A single characteristic length used in furnace/chamber radiation calculations, standing in for the actual 3D geometry of the enclosure. Roughly, factor × (enclosure volume ÷ total wall area) — a bigger, more open chamber radiates more effectively per unit of wall.
Membrane wall
A furnace wall built from vertical tubes welded together edge-to-edge with a steel strip (a "membrane" fin) between them, forming a continuous gas-tight wall that is also the boiler's heating surface. Standard construction for modern water-tube boiler furnaces.
Fouling
A layer of ash, scale or deposit that builds up on a heat-transfer surface over time and adds thermal resistance (it makes U worse). Entered as a thickness and a conductivity for the deposit layer, not as a single lump resistance, so it scales properly with how thick the layer actually is.

Boiling & circulation

Circulation ratio (CR)
How many kilograms of water circulate through the boiling tubes for every kilogram that actually leaves as steam. A CR of 10 means 10 kg goes around the loop to produce 1 kg of steam, with 9 kg returning as liquid to go around again. Higher-pressure boilers need lower CR to circulate reliably; the site's modules use a fitted correlation against drum pressure as a starting estimate.
Dryness fraction (x)
The steam fraction of a steam-water mixture, by mass. x = 0 is all liquid, x = 1 is all steam. Related to circulation ratio by x ≈ 1/CR for a single pass.
Natural circulation
Water circulates through the boiler on its own, without a pump, because the steam-water mixture in the heated riser tubes is lighter than the plain water in the unheated downcomer tubes — that density difference drives the flow, the same principle as a chimney.
Wall temperature = Tsat
In a boiling section, the metal-to-water side of the tube wall sits very close to the saturation temperature of the water at that pressure, because boiling is such an effective way to move heat. The site's boiling-section modules use Tsat directly, with no added margin.

Flow & convection

Reynolds number (Re)
A dimensionless measure of how turbulent a flow is — the ratio of inertial to viscous forces. Low Re is smooth (laminar) flow, high Re is turbulent. Most of the convection correlations used here are only valid within a stated Re range.
Prandtl number (Pr)
A property of the fluid itself (not the flow) comparing how well it diffuses momentum versus heat. Gases sit around 0.7; liquids vary more widely. Used together with Re in most convection correlations.
Zukauskas correlation
A widely used, experimentally-derived formula (Žukauskas, 1972) for convective heat transfer as a fluid crosses a bank of tubes arranged in rows, accounting for tube pitch, row count and arrangement (aligned vs staggered).
Dittus-Boelter
A standard correlation for convective heat transfer for flow inside a single pipe or duct (as opposed to crossing a tube bank), used here for straight flue-gas ducts and for the inside of steam/water tubes.

Radiation

Hottel-type emissivity
A method (after Hottel & Sarofim) for estimating how strongly a gas mixture radiates heat, built from the concentration and path length of the radiating gases (mainly CO₂, H₂O and SO₂) rather than treating the gas as a simple grey body.
Gas emissivity / absorptivity
How effectively the hot flue gas gives off radiant heat (emissivity) versus how effectively a cooler surface absorbs radiation from the gas (absorptivity). These aren't quite the same number because they depend on different temperatures.

ESP (electrostatic precipitator)

Corona onset voltage
The voltage at which the electric field around a discharge electrode becomes strong enough to ionize the surrounding gas and start a corona discharge — the mechanism that charges fly ash particles. Below this voltage, nothing happens; the ESP has to run above it.
Migration velocity
How fast a charged dust particle drifts sideways toward the collecting plate under the electric field, combining the particle's charge, the field strength, and drag from the gas. This velocity, together with the plate area and gas flow, sets the collection efficiency.
Back corona
A failure mode where the collected dust layer itself becomes electrically stressed enough to generate its own corona discharge in the wrong direction, which re-releases some collected particles and hurts efficiency. More likely with high-resistivity ash. The ESP module checks the dust-layer field against a back-corona limit.
Fly ash resistivity
How strongly the collected ash resists conducting electric charge away to the plate, in ohm-cm. Very low resistivity re-entrains dust; very high resistivity encourages back corona. There's a "best" middle range where ash collects cleanly.

Fuel & combustion

LHV / HHV lower / higher heating value
Two ways to measure fuel energy content. HHV includes the heat recovered by condensing the water formed during combustion; LHV doesn't (that water leaves as vapor in real flue gas, so LHV is the number boiler duty calculations normally use).
Proximate / ultimate analysis
Two standard ways of reporting a solid fuel's composition. Proximate gives moisture, ash, volatile matter and fixed carbon (a quick lab test). Ultimate gives the elemental breakdown — carbon, hydrogen, oxygen, nitrogen, sulfur, chlorine, ash — which combustion calculations actually need.
As-received / dry basis
Whether a fuel composition is reported including its natural moisture ("as-received") or with that moisture mathematically removed ("dry basis"). The same fuel gives different-looking percentages depending which basis is used, so it matters which one a value is quoted on.
Particle trajectory model
Following a single representative fuel particle (or a small size range) through drying, devolatilization and char burnout as it moves through the furnace or along a grate, rather than modeling the whole fuel bed at once. Useful for checking whether a particle finishes burning before it runs out of residence time.

Ash behavior

Slagging / fouling index
A number calculated from a fuel's ash oxide composition (ratios of basic to acidic oxides, alkali content, and similar) that correlates with how likely that ash is to form sticky, hard-to-remove deposits on furnace walls (slagging) or convective tube banks (fouling). These are empirical screening indices, not a guarantee — always cross-checked against the fuel's actual melting behavior where possible.
Ternary phase diagram
A triangular chart used to estimate the melting behavior of a three-oxide-dominated ash system, based on where the ash's composition falls relative to known low-melting-point regions mapped out for that oxide system.

Humid air

Psychrometric properties
The set of properties describing moist air together — dry-bulb temperature (the plain thermometer reading), wet-bulb temperature (cooled by evaporation), dew point (where condensation starts), and humidity ratio (mass of water vapor per mass of dry air).

Deaerator

Deaerator operating pressure
A deaerator always operates at saturation, so its pressure and temperature are directly linked by the steam tables — picking one picks the other. "Standard" units run around 0.2–1.0 barg (110–120°C), enough for reliable oxygen removal. "Elevated" units run higher, up to roughly 150°C, mainly to push downstream feedwater and metal temperatures further above a boiler's acid dew point when fuel sulfur or flue-gas chemistry makes that a real risk.
Deaerator heat balance
A direct-contact mixing calculation: heating steam condenses straight into the incoming condensate and makeup water (no heat-exchanger surface between them), and all three streams leave as one saturated liquid at the deaerator's operating pressure. The steam flow needed is whatever balances the energy books.
Storage retention time
How long the deaerator's water-storage section can keep feeding the boiler on its own if the deaerator's steam or water supply is suddenly lost — long enough for an operator or automatic system to shut the boiler down in an orderly way rather than running it dry. Ten minutes at full design flow is the most commonly cited guideline.
NPSH (Net Positive Suction Head)
How far the pressure at a pump's suction sits above the liquid's own vapor pressure, expressed as a height of liquid. If NPSH available falls below what the pump needs (NPSH required), the liquid flashes to vapor inside the pump — cavitation — which damages the impeller and collapses the flow. For a deaerator, because the stored water is already at saturation, elevation above the pump is essentially the only thing that creates NPSH margin.
Droplet heat and mass transfer
Two separate physical processes happen on a falling spray droplet at the same time: steam condensing on its surface heats it toward saturation (a convective heat-transfer problem), while dissolved oxygen already inside the droplet has to diffuse out to that same surface before it can be stripped away (a much slower, diffusion-limited mass-transfer problem). The second one is usually what actually limits how well a deaerator performs.
Whitaker's correlation
A standard, widely-used formula (S. Whitaker, 1972) for the Nusselt number of forced convection over a single sphere, covering a wide range of Reynolds and Prandtl numbers. Originally developed for ordinary convective heating/cooling of solid spheres; applied to condensing droplets as an approximation, it tends to understate the true heat transfer rate because it doesn't separately capture the latent heat released right at the surface.
Diffusion in a sphere (Crank's solution)
The classical mathematical solution for how a dissolved species diffuses out of (or into) a sphere over time, assuming the concentration at the surface is fixed. It's the direct mass-transfer analog of transient heat conduction in a sphere, and gives a clean way to estimate how long a droplet needs before dissolved oxygen in its core has had time to reach the surface and be stripped away.

Steam turbines

Isentropic efficiency (turbine stage)
The ratio of the actual enthalpy drop across a stage to the enthalpy drop you'd get from a reversible, no-loss (isentropic) expansion to the same exit pressure. A stage with 85% isentropic efficiency delivers 85% of the ideal work — the rest becomes added entropy (and a slightly higher, wetter, or hotter exit state than the ideal case).
Impulse vs. reaction blading
Two ways a turbine stage extracts work from steam. In an impulse stage, steam's pressure drops entirely across the fixed nozzles; the moving blades just redirect the already-fast jet, with no further pressure drop across them. In a reaction stage, pressure drops across both the fixed and moving rows, so the moving blades themselves act a little like a nozzle too. Impulse stages handle a large pressure drop per stage and tolerate blade-tip leakage well, which suits small, high-pressure, low-flow turbines. Reaction stages are more efficient per stage but need more of them, and lose more to tip leakage — better suited to larger, higher-flow machines. Many real turbines blend both along their length.
Wilson line
The point in a wet-steam expansion where condensation actually starts. Steam can remain supersaturated (dry past the point where equilibrium tables say it should start condensing) for a short way into the wet region, typically until dryness drops to around 96–97%, before tiny droplets nucleate. Below that there's also a separate, more conservative design guideline: once average wetness exceeds about 10–12% (dryness below roughly 0.88–0.90), droplet impact erosion on the last-stage blades becomes a real concern, and Baumann's rule estimates the efficiency penalty at roughly 1% per 1% of average wetness in the affected stages.

Turbine off-design

Stodola's Ellipse (Cone) Law
A long-established relationship (Aurel Stodola, 1927) between a turbine stage group's inlet pressure, exit pressure and mass flow: M² ∝ (P₁²−P₂²)/(P₁v₁). Plotted as flow against pressure ratio, the curve traces an ellipse — hence the name. It holds without needing to know the stage's actual blade geometry, which is what makes it useful for predicting how a turbine behaves away from its design point. Assumes an unchoked group with many stages; real groups with very few stages, or running near choked flow, deviate from the ideal curve.

Condenser cooling

Cooling tower Approach
How close a cooling tower gets the water to the theoretical limit set by the weather: the difference between the cold water leaving the tower and the ambient wet-bulb temperature. A smaller approach needs a bigger, more expensive tower. Typical industrial values run 3–8°C.
Cooling tower Range
How much the cooling water cools down across the tower — the hot water returning from the condenser minus the cold water leaving the tower. Range is set by how much heat the condenser rejects into the water, not by the tower itself. Typical values run 5–12°C.
Condenser TTD (Terminal Temperature Difference)
The gap between the steam's condensing (saturation) temperature and the cooling water's own temperature as it leaves the condenser. It's a measure of how close the heat exchanger itself gets the two fluids together; a clean, well-sized surface condenser typically runs a TTD of 3–5°C.
ITD (Initial Temperature Difference)
The air-cooled-condenser equivalent of TTD: the gap between the steam's condensing temperature and the ambient dry-bulb temperature. Air-cooled systems are limited by dry-bulb (not wet-bulb) temperature and need a much larger temperature difference to reject the same heat as water, which is why ITD is typically 15–30°C — and why air-cooled condensers generally can't reach as low a pressure as water-cooled ones.

Thermoelectric generation

Figure of merit, ZT
A single dimensionless number, ZT = α²T/(ρκ), that captures how good a thermoelectric material is at converting heat to electricity: Seebeck coefficient (α, voltage generated per degree) squared, times temperature, over the product of electrical resistivity (ρ) and thermal conductivity (κ). A good thermoelectric material wants a high Seebeck coefficient and low electrical resistivity (both help electricity flow easily) but also low thermal conductivity (so the temperature difference driving it doesn't just leak straight through by conduction) — three properties that are naturally hard to get all pulling the same way at once, which is why high-ZT materials are rare.
Ioffe maximum efficiency
The theoretical best-case conversion efficiency of an ideal thermoelectric leg between two temperatures, derived by A.F. Ioffe in 1957: ηmax = (Carnot efficiency) × (√(1+ZT)−1)/(√(1+ZT)+Tc/Th). It's always below the Carnot limit for the same two temperatures, and approaches it only as ZT → ∞. Real modules run below even this ideal-leg number once contact resistance and other losses are included.

Site conventions

Status badges (Validated / Reference-based / Preliminary)
How much checking stands behind a given module. Explained in full, with the check for every module, on the Validation & Limitations page.
The pre-filled numbers
Every field opens with a complete, self-consistent example boiler already filled in, so you can see a working result immediately. They're a starting point, not a requirement — replace them with your own design values whenever you have them.