Deaerator / Thermal & Mass Balance

Deaerator Thermal & Mass Balance

Reference-based what this means

Condensate return, makeup water and heating steam mix to a single saturated state at the deaerator's operating pressure. Fix the operating point and the inlet streams, and the steam demand follows directly from an energy balance.

? New here? How to use this calculator

What this answers: how much heating steam a deaerator needs to bring condensate return and cold makeup water up to its saturated operating temperature — the single biggest steam consumer most plants don't think to check.

This is module 1 of 4. Its output (total feedwater flow, operating temperature) feeds the other three: storage tank size, pump NPSH/elevation, and the droplet heat-transfer check. Not cross-linked automatically yet — carry the numbers across by hand.

The numbers already in the fields are a plausible example, not a template you must match. Overwrite them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Operating Point?
barg
Condensate Return
kg/s
°C
Makeup Water
kg/s
°C

Deaerator Saturated Condition

Heating Steam Demand?

Total Feedwater Output

Carry this flow and temperature into Storage Tank Sizing, and the operating pressure into NPSH & Elevation.
Reference-based. This is a standard direct-contact heater energy balance (steam condenses and mixes directly with the water, no separate heat-exchanger surface) using the IAPWS-IF97 property engine shared with the Steam Table module. The 110–120°C standard-pressure range and the elevated-pressure, acid-dew-point rationale are common power-plant design practice; see Validation & Limitations.