Steam Turbine / Off-Design
A turbine stage group's inlet, exit and flow don't move independently — fix any two and Stodola's Ellipse (Cone) Law gives the third. Run one group at a time; apply it again, group by group, to chain a full Steam Turbine Expansion case to a new load.
What this answers: you know how one stage group of a turbine behaves at its design point (inlet pressure, exit pressure, flow). At a different load, one of those three changes and you need to know what happens to the other two. Stodola's Law gives a fixed relationship between them for that group's geometry, with no need to know the actual blade dimensions.
Pick what's fixed and what you're solving for with the mode buttons below — which one applies depends on your situation. A governing (first) stage usually has its exit pressure set by everything downstream, so you'd fix exit pressure and solve for inlet. A group feeding a fixed extraction load might have inlet fixed by an upstream group instead.
The numbers already in the fields are a plausible example — not a template you must match. Overwrite them with your own design point; the results update as you type.
Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.
Quick reaction — was this calculator useful?
Was this calculator useful? Tell us what's missing or what you'd like to see next.