PlantAISim

Steam Turbine / Expansion & Extraction

Steam Turbine Expansion & Extraction

Validated what this means

Governor valve throttling, steam seal leak-off, and stage-by-stage expansion through any number of extraction points — back-pressure or condensing — using the same IAPWS-IF97 engine as the Steam Table module, with a Wilson-line wetness check at the wet end.

? New here? How to use this calculator

What this answers: given inlet steam and a path of expansion stages (each with its own exit pressure and efficiency), how much power the turbine produces, what state the steam is in at every extraction point, and whether the final stage is getting dangerously wet.

Add or remove stages with the buttons below the stage list. The last stage's exit pressure is always the turbine's final exhaust — back-pressure or condensing. Every stage before that is an extraction point: whatever flow you draw off there leaves the turbine (to process steam or a feedwater heater) and doesn't do any more work downstream.

The numbers already in the fields reproduce a published textbook example (see Validation below) — not a template you must match. Overwrite them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Inlet & Governor Valve
kg/s
% of main flow
bar(a)
°C
% pressure drop, throttling (h constant)
Suggests a per-stage efficiency range only — edit any stage's efficiency directly.
Exhaust
bar(a) — condensing: from Cooling Water module
Expansion Stages & Extraction Points

The last row's exit pressure is the exhaust pressure above and its extraction flow is ignored (everything remaining goes to exhaust).

Inlet State

Stage-by-Stage Expansion?

Power & Steam Rate

Wetness & Wilson Line Check?

Validated against: D.J. Dunn, Applied Thermodynamics Tutorial 1 — Advanced Steam Cycles (freestudy.co.uk), Worked Examples 3 & 5. Default inputs reproduce Worked Example 5 (pass-out turbine, 60 bar/500°C, 4 kg/s extracted at 3 bar, exhaust 0.09 bar, overall η=0.9): textbook answer 37.34 kg/s for 40 MW. This calculator's stage-by-stage method (proper isentropic efficiency applied to each stage) gives 36.6 kg/s — about 2% different, because the textbook's intermediate extraction enthalpy is read off a straight line on an h-s chart rather than computed stage-by-stage. See Validation & Limitations for the full comparison.

Quick reaction — was this calculator useful?

Was this calculator useful? Tell us what's missing or what you'd like to see next.

Send Feedback