PlantAISim

Boiler Heat Transfer Train / Natural Circulation Check

Thermal Head

Reference-based what this means

Checks whether Natural Circulation has enough driving force to push flow around the loop — before sizing any individual riser (Furnace, Screen Tube, Evaporator...). Driving force comes from the density difference between the cool downcomer and the boiling risers; it must exceed the sum of friction and acceleration losses around the whole loop, including the downcomer itself.

? New here? How to use this calculator

What this answers: Checks whether natural circulation actually has enough driving force to push water around the loop, before you size any individual riser tube bank.

The numbers already in the fields are a complete, working example — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Drum & Boiler Geometry
barg
bar
m
Circulation Ratio & Riser Dryness?
leave 0 to auto-compute from drum pressure
leave 0 to use 1/CR
Downcomer
kg/hr — leave 0 to auto-compute from CR & steam production
kg/hr
mm
m
mm — commercial steel pipe, typical
Drum Internals
Pa — from vendor data; no universal standard value, engineering estimate
Riser Circuits — Friction + Acceleration ΔP

Enter each riser circuit's own Friction+Acceleration pressure drop (NOT including its gravity/static-head term — that's already netted into the driving-force calculation above). Take these from each component's own module (Furnace, Screen Tube, Evaporator...).

Driving Force?

Downcomer Resistance

Circulation Balance?

Driving Force = (ρ_downcomer − ρ_riser,avg) × g × H. ρ_riser,avg is the homogeneous two-phase mixture density at the average dryness fraction across all risers (harmonic/volume-weighted, same convention as Furnace/Screen Tube). Total Resistance = Downcomer friction (Darcy-Weisbach/Colebrook) + the sum of each riser circuit's own Friction+Acceleration ΔP (their gravity terms are excluded here since that effect is already captured in the Driving Force term above — including it again would double-count). Balance: Driving Force ≥ Total Resistance means Natural Circulation is adequate; if not, the design needs a larger downcomer, taller boiler, or assisted/forced circulation.