PlantAISim

Combustion & Emissions / Advanced Combustion Models

Suspension Firing Boiler

Reference-based what this means

Hybrid furnace model: fine particles are tracked as a ballistic trajectory (drag + gravity) burning in suspension (Drying → Pyrolysis → Char), while coarser particles land on the grate and continue burning there — both regimes active in the same furnace, as in a typical bagasse or similar biomass boiler. Sweeps 8 particle sizes across the 0.15–3.0 mm range.

? New here? How to use this calculator

What this answers: Models a furnace where fine fuel particles burn in mid-air while coarser particles land and burn on the grate — both happening at once.

The numbers already in the fields are a complete, working example — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Fuel (dry-basis proximate)
%
%
%
%
Feed & Furnace Geometry
m/s
° from horizontal
m
m — above this, a particle exits with the flue gas unburned/partially burned
m
kg/m³
In-Flight (Suspension) Zone
°C
°C
m/s
On-Grate Zone (once landed)
°C
m/s
m/s
mm/s
mm
°C
°C
Gas Composition (mol%, shared for property lookup)
Char Kinetics
%
%
cm/s
kg/m³
fuel burning in-flame is typically high quality from the start
ash-layer resistance around the char core reduces this once on the grate

Particle Size Sweep — Outcome Summary

d_p (mm)OutcomeExit/Land x (m)Exit/Land y (m)Time (s)Burnout %T_p (°C)

Trajectory (all sizes)?

Single representative-particle model per size (Eulerian-Lagrangian), run independently for each of 8 log-spaced diameters across 0.15–3.0 mm — not a full population/PSD-weighted mass balance. In-flight heat transfer uses free-stream Ranz-Marshall correlation (Nu=2+0.6·Re^0.5·Pr^⅓); once a particle reaches the bed surface it switches to packed-bed correlations (Nu=2+1.1·Pr^⅓·Re^0.6, with the 0.1 packed-bed reduction factor), matching the Fixed-Bed Firing Model. Pyrolysis and char kinetics reuse the same general (non-fuel-specific) Arrhenius/two-reaction forms as the Fixed-Bed module. Bed shrinkage during pyrolysis is a simplified linear interpolation. Burnout% shown is Fixed-Carbon burnout for particles that reach the char stage; particles still drying/pyrolyzing at exit or landing show 0%.

Quick reaction — was this calculator useful?

Was this calculator useful? Tell us what's missing or what you'd like to see next.