Boiler Heat Transfer Train / Steam-Water Separation
Thermodynamically, the drum is a flash tank: two-phase mixture arrives from the risers (grouped here as Furnace-side and Evaporator-side circuits, add/remove as your boiler's actual routing requires), steam is separated by the cyclone/demister, and the remaining saturated liquid mixes with incoming Economizer feedwater by enthalpy balance to set the drum water temperature (slightly subcooled below T_sat, not exactly at it).
What this answers: Checks the drum's mass and energy balance: how much of the incoming two-phase flow actually leaves as steam, and what temperature the drum water settles at.
The numbers already in the fields are a complete, working example — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.
Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.
Quick reaction — was this calculator useful?
Was this calculator useful? Tell us what's missing or what you'd like to see next.