PlantAISim

Boiler Heat Transfer Train / Tube Bank

Screen Tube Heat Transfer

Reference-based what this means

Tube-bank cross-flow heat transfer — Hottel radiation (same engine as Furnace), Zukauskas (1972) convection correlation for banks of tubes in cross-flow, boiling heat transfer, and fly-ash fouling. Position (before/after Superheater) doesn't change the physics here — set it via the Flue Gas Temperature Profile. Inlet may already be partially evaporated (not necessarily saturated liquid).

? New here? How to use this calculator

What this answers: Required tube surface for a screen tube bank — the first row of tubes the flue gas crosses after leaving the furnace.

The numbers already in the fields are a complete, working example — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Flue Gas (from Temperature Profile)
kg/hr
°C
°C
bar
Gas Composition (mol%, wet basis)
Tube Bank Geometry
mm
mm
mm
mm
row-correction factor is looked up automatically below
m — used for both Ao/Ai and the boiling correlation
m
m — net open height between tube rows/headers, not the full furnace height
Water/Two-Phase Side
barg
bar — at the boiler's installation elevation
may already be partially evaporated (e.g. from Furnace)
kg/hr
Tube Wall & Fouling?
W/m·K
micron
W/m·K
mm — commercial steel tube, typical
% of gas-side Q — typical 1.5-3%

Duty & Natural Circulation?

Heat Transfer Coefficients?

Pressure Drop

Heating Surface?

Radiation: same Hottel-type engine as Furnace/Flue Gas Thermal Properties, but Mean Radiating Length uses the tube-bank form L=Factor×(Pitch−D) instead of 3.5×V/A. Convection: Zukauskas (1972) — V_max from the free-stream velocity via an arrangement-dependent factor, Re_max on that velocity, C1/m coefficients depending on Re_max range and ST/SL ratio, with a row-count correction factor. Ao=π×OD×L×N and Ai=π×ID×L×N (full circumference both sides — individual tubes with gaps, unlike Furnace's membrane wall where only Ao uses the full diameter and Ai is halved). Inlet dryness fraction is a direct input since Screen Tube commonly receives already-partially-evaporated flow rather than starting from saturated liquid. This module reports Actual (from your tube-length input) vs Required (from U×LMTD) heating surface as a Rating check.