Boiler Heat Transfer Train / Optional Radiant Zone

Radiation Heat Drop Chamber

Reference-based what this means

An empty, tube-lined radiant chamber some biomass boilers use to shed flue gas temperature by radiation alone before the tube-bank sections — common with fuels like empty fruit bunch (EFB), less common with bagasse. Same physics as the Furnace module (membrane-wall risers, Hottel radiation, gas-side convection, two-phase boiling, Natural Circulation flow) — no combustion occurs here, gas inlet/outlet temperatures come from your Flue Gas Temperature Profile as fixed design choices. Sized directly, no iteration.

? New here? How to use this calculator

What this answers: Same physics as the Furnace module, sized for an empty radiant chamber some boiler designs use to cool flue gas before it reaches the tube banks.

The numbers already in the fields are a complete, working example — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Flue Gas (from Temperature Profile)
kg/hr
°C — from Basic Combustion / Temperature Profile
°C — from Temperature Profile
bar
Gas Composition (mol%, wet basis)
Chamber Geometry
m
m
m — chamber height, used for Volume=W×D×H
m² — real furnaces often aren't simple W×H (sloped walls); override here
m²
L=factor×V/A
m² — for gas velocity/Re; default=Width×Depth, override if the free-flow area differs
mm — membrane-wall tube-row surface, not smooth; adjust from experience (corrugated/riveted-metal range)
m — real riser tube length; used for both Ao/Ai and the boiling correlation
Water Wall Tubes
Front+Rear+Side×2 — real, known design count
mm
mm
W/m·K
micron — biomass furnace typical
W/m·K
mm — commercial steel tube, typical
Steam Drum & Natural Circulation?
barg
bar — at the boiler's installation elevation

Wall temperature = saturation temperature directly (no margin added, per design experience).

Ash Particle Enhancement Factor
% of gas-side Q — typical 1.5-3%, lost to convection through insulation before reaching the tube side

From experience: ash particles enhance overall heat transfer beyond gas-only radiation models. Gas-fired boilers track the correlations closely (factor≈1.0); biomass needs the largest correction (1.5-1.6) due to fly ash particle radiation.

Duty & Natural Circulation?

Heat Transfer Coefficients?

Pressure Drop

Required Heating Surface & Tube Count?

Radiation uses the same Hottel-type correlation validated in the Flue Gas Thermal Properties module (rational-polynomial-in-log(pL), CO2/H2O/SO2, dual T-branches, Hottel & Sarofim absorptivity scaling). Gas-side convection: Dittus-Boelter through a hydraulic-diameter duct (grate/free-flow cross-section). Tube-side: Dittus-Boelter (single-phase) plus a two-phase boiling correlation, combined additively (Chen-style superposition — the specific boiling correlation form is mechanically reproduced from a real reference design but its literature source hasn't been independently identified). Overall U referenced to outside heating surface (bare-tube OD×length×count convention), with the inside (water-side) term properly scaled by the A_o/A_i area ratio. Water/steam flow required is derived from Natural Circulation theory: Circulation Ratio CR=−5.914·ln(P_drum,barg)+35.234 (biomass-specific correlation), target dryness fraction x=1/CR, Flow=Q/(h_fg×x). Gas inlet/outlet temperatures are fixed design inputs (from the Flue Gas Temperature Profile module) — this module solves directly for required area, no iteration. It does not solve multi-circuit Natural Circulation flow apportionment (this Chamber, Furnace, Screen Tube, and any other risers all sharing one drum) — the flow reported here is this section's own requirement in isolation; use the Thermal Head module to check the combined loop.