PlantAISim

Boiler Heat Transfer Train / Radiant Section

Furnace Heat Transfer

Reference-based what this means

Required water-wall heating surface for the radiant furnace — gas inlet/outlet temperatures come from your Flue Gas Temperature Profile (fixed design choices, not solved here). Gas-side radiation (Hottel-based, same engine as Flue Gas Thermal Properties) plus convection, tube-side boiling heat transfer, fly-ash fouling, and the Natural Circulation flow this section needs to hit its target dryness fraction. Combustion is complete by this point — this module is pure heat transfer, sized directly with no iteration.

? New here? How to use this calculator

What this answers: "How much water-wall tube surface does my furnace need, given the fuel, gas flow and grate design I already have?" It's one piece of a full boiler — the gas temperatures it starts from are decisions made upstream (in Flue Gas Temperature Profile), and its own results feed the next section downstream.

The numbers already in the fields are a complete, working example boiler (100 t/hr steam, 45 barg) — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Flue Gas (from Temperature Profile)
kg/hr
°C — from Basic Combustion / Temperature Profile
°C — from Temperature Profile
bar
Gas Composition (mol%, wet basis)
Furnace Geometry
m
m
m — chamber height, used for Volume=W×D×H
m² — real furnaces often aren't simple W×H (sloped walls); override here
m²
L=factor×V/A
m² — for gas velocity/Re; default=Width×Depth, override if the free-flow area differs
mm — membrane-wall tube-row surface, not smooth; adjust from experience (corrugated/riveted-metal range)
m — real riser tube length; used for both Ao/Ai and the boiling correlation
Water Wall Tubes
Front+Rear+Side×2 — real, known design count
mm
mm
W/m·K
micron — biomass furnace typical
W/m·K
mm — commercial steel tube, typical
Steam Drum & Natural Circulation?
barg
bar — at the boiler's installation elevation

Wall temperature = saturation temperature directly (no margin added, per design experience).

Ash Particle Enhancement Factor
% of gas-side Q — typical 1.5-3%, lost to convection through insulation before reaching the tube side

From experience: ash particles enhance overall heat transfer beyond gas-only radiation models. Gas-fired boilers track the correlations closely (factor≈1.0); biomass needs the largest correction (1.5-1.6) due to fly ash particle radiation.

Duty & Natural Circulation?

Heat Transfer Coefficients

Pressure Drop

Required Heating Surface & Tube Count?

Radiation uses the same Hottel-type correlation validated in the Flue Gas Thermal Properties module (rational-polynomial-in-log(pL), CO2/H2O/SO2, dual T-branches, Hottel & Sarofim absorptivity scaling). Gas-side convection: Dittus-Boelter through a hydraulic-diameter duct (grate cross-section). Tube-side: Dittus-Boelter (single-phase) plus a two-phase boiling correlation, combined additively (Chen-style superposition — the specific boiling correlation form is mechanically reproduced from a real reference design but its literature source hasn't been independently identified). Overall U referenced to outside heating surface (bare-tube OD×length×count convention), with the inside (water-side) term properly scaled by the A_o/A_i area ratio. Water/steam flow required is derived from Natural Circulation theory: Circulation Ratio CR=−5.914·ln(P_drum,barg)+35.234 (biomass-specific correlation), target dryness fraction x=1/CR, Flow=Q/(h_fg×x). Gas inlet/outlet temperatures are fixed design inputs (from the Flue Gas Temperature Profile module) — this module solves directly for required area, no iteration. It does not solve multi-circuit Natural Circulation flow apportionment (Furnace vs Screen vs Chamber risers sharing one drum) — the flow reported here is this section's own requirement in isolation.

Quick reaction — was this calculator useful?

Was this calculator useful? Tell us what's missing or what you'd like to see next.

Send Feedback