Reference-based what this means

Single-particle Lagrangian trajectory through a mass-burn/travelling grate — Drying, Pyrolysis, and Char Burnout stages in sequence, driven by locally-supplied zone gas temperatures (e.g. from a CHEMCAD simulation). Eulerian-Lagrangian approach, following the structure of published fixed-bed combustion literature (Duffy 2012; Yang, Ryu, Nasserzadeh, Swithenbank — FLIC).

? New here? How to use this calculator

What this answers: Follows one fuel particle through drying, releasing its volatiles, and burning out its char as it travels along a moving grate.

The numbers already in the fields are a complete, working example — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Fuel (dry-basis proximate)?
%
%
%
%
Particle & Bed
mm
kg/m³
%wt
fraction of VM volume retained as void
mm
bed-radiation vs overbed-radiation split
Grate & Feed
m
mm/s
°C
m/s — drying zone (underfire air, before pyrolysis gas volume adds)
m/s — pyrolysis+char zones (includes pyrolysis gas product volume, larger than primary air alone)
°C
Zone Gas Temperatures (from CHEMCAD or equivalent)
°C
°C
°C
Local Gas Composition (mol%, shared — used to auto-derive ρ/μ/k/Cp/Pr per zone via Flue Gas Thermal Properties)

O2/CO2 free-stream partial concentration for char kinetics is derived from this same composition at the char-zone temperature and pressure.

Char Reaction Kinetics
% — local, near primary-air entry; typically much richer than bulk flue gas O2%
%
cm/s — Sh×D_binary/d_p; enter directly (binary diffusivity through a packed bed is case-specific)
kg/m³ — includes intra-particle porosity from pyrolysis shrinkage; NOT auto-derived (particle shrinkage during pyrolysis isn't tracked) — enter your own value, e.g. from a true-density/porosity calc or a reference case
default 0.5 — real char cores face significant resistance to O2/CO2 reaching them (ash layer buildup around the carbon core, especially thick for fuels like EFB); 1.0 assumes no such resistance

R1: C+O2 (Ea=79.5 kJ/mol, within the commonly-cited Zone-II range). R2: C+CO2 Boudouard (Ea=175.0 kJ/mol — slightly below the 200-250 kJ/mol most often cited for biomass char specifically, but within the wider literature spread). Combined mass-transfer/kinetic resistance, shrinking-particle constant-density model.

Stage Summary

Particle Temperature Along Grate

Composition Decay Along Grate

Trajectory Table (sampled)?

Staget (s)x (m)T_p (°C)Mass (g)Moist %Volatile %Fixed C %
This is a single representative-particle model (Eulerian-Lagrangian), not a full bed-height-resolved 2D CFD solve like FLIC itself. Zone gas temperatures are supplied directly (e.g. from a separate CHEMCAD or similar gas-phase simulation) rather than solved via a fully-coupled gas/solid energy balance — this is a deliberate simplification consistent with the source model. Kinetics: single-step Arrhenius pyrolysis; two parallel char reactions (oxidation, Boudouard gasification) with combined mass-transfer/kinetic resistance. Bed shrinkage is a simplified linear interpolation during pyrolysis, not the full geometric shrinkage submodel described in the fixed-bed combustion literature.

Quick reaction — was this calculator useful?

Was this calculator useful? Tell us what's missing or what you'd like to see next.

Send Feedback