PlantAISim

Software Suite / Module 01

Industrial Fan Design & Fan Curve Calculator

Reference-based what this means

Backward-curved centrifugal fan — single-curve blade geometry, checked against target impeller diameters, with the full static-pressure-versus-flow performance curve.

? New here? How to use this calculator

What this answers: Sizes a centrifugal fan's impeller and blades for a target flow and pressure, and plots the resulting performance curve.

The numbers already in the fields are a complete, working example — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Impeller Geometry

mm
mm
deg.
deg.
mm
mm
blades
RPM

Volute, Suction & Operating Gas

mm
mm
mm
mm
mm
mm
°C
kg/m³
Pa·s

Single-Curve Blade Solver

The half-angle d defines the single-curve blade profile. Solve it so the geometric outlet radius matches your target D2 exactly, or set it manually to check an existing profile.

deg.

Geometry Check

Blade angle span, O = 2d + (β2 − β1)
Inlet radius, r1 = D1 / 2
Computed outlet radius, r2
Computed outlet diameter, 2 × r2
Target outlet diameter, D2
Single-curve blade radius, L

Checked against the closed-form single-curve blade relations for D1, D2, β1, β2 and d — the same geometric solution used in the source design workbook.

Fan Performance Curve

Computed live from the design's turbomachinery model (slip factor, recirculation, shock, friction and volute losses, mechanical drag torque) — change any input above and the curve recalculates.

Quick reaction — was this calculator useful?

Was this calculator useful? Tell us what's missing or what you'd like to see next.