Boiler Heat Transfer Train / Tube Bank

Evaporator Bank — Riser

Reference-based what this means

The riser side of an evaporator bank tube bundle (Furnace/Chamber → Screen Tube → this bank → drum) — same Zukauskas (1972) tube-bank engine as Screen Tube. Named separately from the Downcomer variant so the two can be linked independently once cross-module Natural Circulation solving is built. Inlet may already be partially evaporated.

? New here? How to use this calculator

What this answers: Required tube surface for the riser side of an evaporator bank, where the water-steam mixture is heading back up toward the drum.

The numbers already in the fields are a complete, working example — not a template you must match. Overwrite any of them with your own design's values; the results update as you type.

Unfamiliar term? Look for a ? next to a field label, or browse the full Glossary.

Flue Gas (from Temperature Profile)
kg/hr
°C
°C
bar
Gas Composition (mol%, wet basis)
Tube Bank Geometry
mm
mm
mm
mm
row-correction factor is looked up automatically below
m — used for both Ao/Ai and the boiling correlation
m
m — net open height between tube rows/headers
Water/Two-Phase Side
barg
bar — at the boiler's installation elevation
may already be partially evaporated (e.g. from Furnace)
kg/hr
Tube Wall & Fouling?
W/m·K
micron
W/m·K
mm — commercial steel tube, typical
% of gas-side Q — typical 1.5-3%

Duty & Natural Circulation?

Heat Transfer Coefficients?

Pressure Drop

Heating Surface?

Radiation: same Hottel-type engine as Furnace/Flue Gas Thermal Properties, but Mean Radiating Length uses the tube-bank form L=Factor×(Pitch−D) instead of 3.5×V/A. Convection: Zukauskas (1972) — V_max from the free-stream velocity via an arrangement-dependent factor, Re_max on that velocity, C1/m coefficients depending on Re_max range and ST/SL ratio, with a row-count correction factor. Ao=π×OD×L×N and Ai=π×ID×L×N (full circumference both sides — individual tubes with gaps, unlike Furnace's membrane wall where only Ao uses the full diameter and Ai is halved). Inlet dryness fraction is a direct input since Screen Tube commonly receives already-partially-evaporated flow rather than starting from saturated liquid. This module reports Actual (from your tube-length input) vs Required (from U×LMTD) heating surface as a Rating check.